6403DZE Series Pressure Switch
Brand: Custom Control Sensors, LLC (CCS)Specifications
- Highly reliable devices utilizing the CCS Dual-Snap® Belleville disc spring principle pioneered by CCS’ engineers.
- Engineering based on aerospace technology.
- Rigid and internally adjustable for convenient field set point adjustment.
- Repeatable and stable set points
- Vibration- and shock-resistant.
- High cycle life.
- High over-pressure capability. (System and Proof)
- Various options for electrical ratings to meet a wide range of application requirements and media capability.
Specifications
Pressure Type
- Differential Pressure
Area Classification
- Hazardous Area
Approvals
- ATEX
- CE
Field Adjustable or Pre-Set Set Point
- Field Adjustable
Process Connection Type & Size
- 1/4"-18 NPT Female
Process Connection Material
- Stainless Steel
Diaphragm Material
- Polyimide
- Stainless Steel
NACE
- NACE MR 0175 / ISO 15156
O-Ring
- Viton
Enclosure Rating
- IP 66
- IP 67
- NEMA 4
- NEMA 7
- NEMA 9
- NEMA 13
Electrical Connection Size
- M20
Electrical Termination Type
- Terminal Strip
Electrical Contacts Form
- SPDT
- DPDT
Electrical Contacts Material
- Silver
- Gold
Voltage Electrical Rating
- VAC 0 - 250
- VAC 251 - 480
- VDC 0 - 125
- VDC 126 - 250
Ampere Rating
- 0.2 to 15 A
SIL Level
- SIL 2
- SIL 3
RoHS Compliance
- Yes
Housing Material
- Aluminum
Gender
- Female
Proof Pressure - Low Over High
- bar: 27.6
- kPa: 2,758
- psig: 400
Proof Pressure - Both Ports
- bar: 52
- kPa: 5,171
- psig: 750
Proof Pressure - High Over Low
- bar: 52
- kPa: 5,171
- psig: 750
Set Point Range - Decreasing
- bar: 0.027 to 4.895
- kPa: 2.689 to 489.5
- psi: 0.39 to 71
Electrical Assembly
- Hermetic Seal
Set Point Range - Increasing
- bar: 0.097 to 5.171
- kPa: 9.653 to 517.1
- psi: 01.4 to 75
Standard Features
- Integral Junction Box
Deadband, Approximate
- bar: 0.07 to 0.28
- kPa: 7.0 to 27.6
- psi: 1.01 to 4
Service
- Sweet - Oil & Gas
Electrical Certification
- ATEX - Certificate No. Baseefa 04-ATEX-0113. Baseefa Certified for Potentially Explosive Atmospheres Electrical Assembly Series. in Compliance with EN 60079-0: 2004, EN 60079-1: 2004 & EN 50281-1-1: 1998 + Amendment 1. (Standard)
Operating Temperature
- -40° to 86° C (-40° to 187° F)
System Pressure
- bar: 27.6
- kPa: 2,758
- psig: 400
Electrical Rating
- 0.5 A at 125 Vdc
- 0.2 A at 250 Vdc
- 5 A at 28 Vdc
- 11 A at 125/250 Vac Resistive
- 15 A at 125/250/480 Vac Resistive
Electrical Connectors
- M20 x 1.5
Area Classification
- Hazardous Area