Approvals & Certifications
Set Point Range - Increasing - psi
- Minimum: 1.4
- Maximum: 5000
Set Point Range - Decreasing - psi
- Minimum: 0.4
- Maximum: 4520
Set Point Range - Increasing - kPa
- Minimum: 9.65
- Maximum: 34473.79
Set Point Range - Decreasing- kPa
- Minimum: 2.75
- Maximum: 31164.3
Set Point Range - Increasing - bar
- Minimum: 0.09
- Maximum: 345
Set Point Range - Decreasing - bar
- Minimum: 0.03
- Maximum: 312
Deadband, Approx. - bar
- Minimum: 0.07
- Maximum: 33.1
System Pressure - Max.
- 500 psig : 34.5 bar : 3447 kPa
- 5000 psig : 345 bar : 3447 kPa
Proof Pressure - Max.
- 750 psig : 51.7 bar : 5171 kPa
Process Connection Type & Size
- 1/4" BSP
- 1/2"-14 NPT Female
- 1/2"-14 NPT Female - Welded Capsule, No O-Ring
Process Connection Material
- Stainless Steel
- Monel
- Hastelloy C-276
Diaphragm Material
- Stainless Steel
- Monel
- Hastelloy C-276
- Viton Dacron
O-Ring
- Ethylene Propylene
- Viton
- No O-Ring c/w Welded Capsule
Enclosure Rating
- IP 65
- IP 66
- NEMA 4
- NEMA 4X
- NEMA 13
Reset Function - Auto or Manual
- Auto
- Manual on Increasing Pressure
Electrical Connection Size
- 3/4" NPT Female Conduit Connection
- M20
Electrical Termination Type
Electrical Contacts Material
Voltage Electrical Rating
- 0 - 250 VAC
- 251 - 480 VAC
- 0 - 125 VDC
- 126 - 250 VDC
Operating Temperature
- -40° to 86° C (-40° to 187° F)
O-Ring Material
- Ethylene Propylene (EPR)
- Viton
Deadband, Approximate
- bar: 0.07 to 33.1
- kPa: 6.9 to 3,309
- psig: 1 to 480
Approvals & Certifications
- CE
- CRN - Canadian Registration Number
- CRN - Alberta
- CRN - British Columbia
- CRN - Manitoba
- CRN - N.W. Territories
- CRN - Saskatchewan
- CSA
- cUL
- EMC
- LVD
- PED
- RoHS
- UL
System Pressure
- bar: 34.5 to 345
- kPa: 3,447 to 34,474
- psig: 500 to 5,000
Set Point Range - Decreasing
- bar: 0.03 to 312
- kPa: 2.8 to 31,164
- psig: 0.4 to 4,520
Process Connection Material
Standard Features
- Internal Case Ground
- Weatherproof
Electrical Connectors
- Terminal Strip - Internal
Diaphragm Material
- Stainless Steel
- Hastelloy C-276
- Monel
- Viton Dacron
Proof Pressure
- bar: 51.7 to 517
- kPa: 5,171 to 51,711
- psig: 750 to 7,500
Set Point Range - Increasing
- bar: 0.09 to 345
- kPa: 9.7 to 34,473.7
- psig: 1.4 to 5,000
Manual Reset
- Manual Reset on Increasing Pressure
Electrical Rating
- 1 A at 125 Vac, 50/60 Hz
- 15 A at 125/250/480 Vac Resistive, 0.4 A at 125 Vdc, 0.2 A at 250 Vdc
- 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc