Accuracy
- ± 0.075 % of Full Scale (At 20° C)
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F) (without LCD)
Approvals & Certifications
Damping Adjustment
- 0 to 60 seconds
- 0.25 to 60 seconds
Diaphragm Material
- 316L Stainless Steel
- Hastelloy C-276
- PTFE
- Tantalum
Display
- 5-Digit LCD (Operational)
Electrical Connectors
- Two 1/2” NPT Female Conduit
Enclosure, Body Material
- 316 Stainless Steel Housing (Only Available with WP Approval)
Environmental Protection
- Explosion-proof
- IP66
- NEMA 4X
Flange Size - 2” (DN 50)
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 16
- 2” (DN 50) - PN 25
- 2” (DN 50) - PN 40
- 2” DN 50 150#
- 2” DN 50 300#
- 2” DN 50 JIS 10K
- 2” DN 50 JIS 20K
Flange Size - 3” (DN 80)
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 16
- 3” (DN 80) - PN 25
- 3” (DN 80) - PN 40
- 3” DN 80 150#
- 3” DN 80 300#
- 3” DN 80 JIS 10K
- 3” DN 80 JIS 20K
Loop Resistance
- 0 to 1500 ohms (Operation)
- 250 to 500 ohms (HART Communication)
Maximum System Pressure
- psi: 11,600 (kPa: 79,979, bar: 799.79)
Mounting
- Direct Mount 1 Flush Diaphragm Seal
Output
- 4-20 mA / (HART Communication)
Pressure Range
- bar: -1 to 586
- kPa: -100 to 58,605
- psig: -14.5 to 8,500
Process Temperature
- -40° to 120° C (-40° to 248° F)
Stability
- ± 0.125 % of Full Scale Output/Year
Temperature Effect
- ± 0.125 % of Span/32° C (90° F)