Approvals & Certifications
Set Point Range - Increasing - psi
- Minimum: 14.5
- Maximum: 6498
Set Point Range - Decreasing - psi
- Minimum: 4.35
- Maximum: 6005
Set Point Range - Increasing - kPa
- Minimum: 99.974
- Maximum: 44802.13
Set Point Range - Decreasing- kPa
- Minimum: 29.9922
- Maximum: 41403.02
Set Point Range - Increasing - bar
Set Point Range - Decreasing - bar
Deadband, Approx. - psi
- Minimum: 10.2
- Maximum: 500
Deadband, Approx. - bar
- Minimum: 0.7
- Maximum: 34.5
System Pressure - Max.
- 5000 psig : 345 bar : 3447 kPa
Process Connection Type & Size
- 1/4"-18 NPT Female
- 1/2"-14 NPT Female
Process Connection Material
Enclosure Rating
- IP 66
- IP 67
- NEMA 4
- NEMA 7
- NEMA 9
- NEMA 13
Electrical Connection Size
Electrical Termination Type
Electrical Contacts Material
Voltage Electrical Rating
- 0 - 250 VAC
- 251 - 480 VAC
- 0 - 125 VDC
- 126 - 250 VDC
System Pressure
- bar: 138 to 689
- kPa: 1,379 to 68,948
- psig: 2,000 to 10,000
Set Point Range - Decreasing
- bar: 0.30 to 414
- kPa: 29.99 to 41,403
- psi: 04.35 to 6,005
Operating Temperature
- -40° to 86° C (-40° to 187° F)
Deadband, Approximate
- bar: 0.7 to 34.5
- kPa: 70.4 to 3,447
- psi: 10.2 to 500
Set Point Range - Increasing
- bar: 1 to 448
- kPa: 99.97 to 44,802
- psi: 14.5 to 6,498
Electrical Certification
- ATEX - Certificate No. Baseefa 04-ATEX-0113. Baseefa Certified for Potentially Explosive Atmospheres Electrical Assembly Series. in Compliance with EN 60079-0: 2004, EN 60079-1: 2004 & EN 50281-1-1: 1998 + Amendment 1. (Standard)
Approvals & Certifications
- ATEX
- CSA
- EMC
- GOST-R
- LVD
- RoHS
- RTN
- UL
Process Connection Material
Electrical Rating
- 0.5 A at 125 Vdc
- 0.2 A at 250 Vdc
- 5 A at 28 Vdc
- 11 A at 125/250 Vac Resistive
- 15 A at 125/250/480 Vac Resistive
Environmental Protection
- IP 66
- IP 67
- NEMA 4
- NEMA 7
- NEMA 9
- NEMA 13
Proof Pressure
- bar: 207 to 896
- kPa: 20,684 to 89,632
- psig: 3,000 to 13,000