Approvals & Certifications
Deadband, Approximate - Bottom of Range
- bar: 0.03 to 0.096
- kPa: 3.5 to 9.6
- psi: 0.5 to 1.4
Deadband, Approximate - Top of Range
- bar: 0.069 to 0.55
- kPa: 6.9 to 55.1
- psi: 1 to 8
Electrical Certification
- c-UL, UL/CSA Explosion-proof: Div. 1, 2 Hermetically Sealed Electrical Assembly P/N 46-1058 (46-1061 for M (DPDT) Model Option), Listed by Both Underwriter's Laboratories, Inc. (File No. E32961) & Canadian Standard Association (CSA) Testing Laboratories
Electrical Rating
- 1 A at 125 Vac, 1 A at 30 Vdc
- 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 0.2 A at 250 Vdc
- 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc
Environmental Protection
- Hazardous Area
- IP54
- IP66
- NEMA 13
- NEMA 4, 7, 9, 13 / IP54, 66
- NEMA 7
- NEMA 9
Operating Temperature
- -40° to 86° C (-40° to 187° F)
Proof Pressure
- bar: 17.24
- kPa: 1,724
- psig: 250
Set Point - Decreasing
- bar: 0.07 to 4.96
- kPa: 6.9 to 496.4
- psig: 1 to 72
Set Point - Increasing
- bar: 0.103 to 5.52
- kPa: 10.4 to 551.5
- psig: 1.5 to 80
System Pressure
- bar: 11.03
- kPa: 1,103
- psig: 160