Exhaust Capacity - Relieving Units Only
- 9 scfm (15.3 m³/hour) Downstream Pressure is psig: 5 (bar: 0.35, kPa: 35) Above Set Pressure
Flow Capacity
- 17 scfm (28.9³/Hour) for psig: 20 (bar: 1.4, kPa: 140)
- 47 scfm (79.9 m³/hour) for psig: 120 (bar: 8, kPa: 800)
Hysteresis
- Within 0.1 % Ful Scale (Repeatability)
Input
- 10-50 mA
- 1-5 Vdc
- 1-9 Vdc
- 4-20 mA
Input Impedance
- Ohms: 1020
- Ohms: 26
- Ohms: 510
- Ohms: 62
Pressure Range
- bar: 0.2 to 1
- kPa: 20 to 100
- psig: 3 to 15
Repeatability
- Within 0.1 % of Full Scale
Supply Pressure
- psig: 18 to 150 (kPa: 120 to 1,000, bar: 1.2 to 10.0)
Supply Pressure Effect
- +0.3 % of Full Scale for psig: 50 (bar: 3.5, kPa: 350) Change
Temperature Range
- -40° to 65° C (-40° to 150° F)