Accuracy
- ± 0.25 % of Full Scale at 25° C (77° F), Display Accuracy ± 0.5 %
Approvals & Certifications
Electrical Connectors
- 3-Wire Removable European Style Terminal Block or 16 to 26 AWG
Loop Resistance
- Current Output: 0-1250 ohms, Max.
- Voltage Output: Load Resistance 1 Kiloohm (Min.)
Media
- Air
- Non-Combustible, Compatible Gases
NACE & NIST
- NIST Traceable Calibration Certificate
Output
- 0-10 Vdc, 3-Wire
- 0-5 Vdc
- 4-20 mA, 2-Wire
Power Requirement
- 10-35 Vdc (2-Wire)
- 17-36 Vdc
- Isolated 21.6-33 Vac (3-Wire)
Pressure Range
- Inches WC: 0 to 200
- kPa: 0 to 2.5
Process Connection Material
Stability
- ± 1 % of Full Scale Per Year
Temperature Range
- -10° to 85° C (14° to 185° F)
Tube Connection
- 3/16” Tube
- Dual Size to Fit 1/8” & 3/16” I.D. Rubber or Vinyl Tubing